ENERGON
The type-tested low-voltage ENERGON switchgear system with withdrawable unit technology is used for applications with high availability and great flexibility.
There are numerous cubicle and module variants which can be used to provide the optimal solution for the varying requirements of customers in infrastructure, industry and energy supply.
NATUS benefits
- Switchgear system arc-tested in accordance with DIN EN 61439
- Isolation of individual function compartments
- Modular cabinet system
- Replacement and refitting possible while running
- Highest personnel protection through internal arc protection zones
- Manufacturer-independent fitting
- Smart switchgear via common bus systems
- Single and dual front arrangement possible
- Multiple busbars in one cubicle possible
- Handy cable connection compartment (400 mm / 600 mm)
- Simple, secure locking system
NATUS highlights
DTS
Patented contact mechanism, double transfer system for safe isolation of the withdrawable unit
- Highly functional withdrawable unit technology
- Safe isolation of the power circuits (back) and control circuits (right) via a mechanical contact process using the operating handle (front)
- Can only be operated when the door is shut, for safety reasons
- High operational safety via operator guidance and locks
- Simultaneous isolation of the power circuits, input and output side
- Provision of operational, test and isolation setting
- No connected cable movement (prevents splaying)
- Internal arc-protected zone in combination with ARC-SAFE distribution busbar
ARC-SAFE
The safe distribution busbar for withdrawable unit and plug-in technology
- Complete, automatic cover of the live phases by the automatic shutter
- Highest internal arc safety via complete enclosure and isolation of the phases from one another
- Internal arc-protected zone in combination with DTS contact system
- Enables modification of the system when live
- IP4X operator protection when door is open
- Also available in fuse block
CONTINUOUS LATCH
The unique door lock sets the standard in safety and ease of use
- Arc-tested functional design
- Simple, easy one-handed operation, no need for tools
- Prevents operational errors (the operating personnel can see remotely that the doors are closed properly)
- Optimal personnel protection
DUAL FRONT
Flexible system configuration with busbars at the top or behind and one or more bars running in parallel.
TECHNICAL DATA
Design-tested Low Voltage | IEC 61439 |
Power Switchgear | DIN EN 61439 |
Testing under conditions due to internal faults (arc fault) |
|
Arcing current Iparc | 65 kA |
Rated operation voltage (Ue) | up to 690 V |
Horizontal main busbars | |
Rated current | up to 6,300 A |
Rated peak withstand current (Ipk) | up to 220 kA |
Rated short-time withstand current (Icw), 1s | up to 100 kA |
Incoming supply, coupler or outgoing feeder (ACB) | up to 6,300 A |
Incoming supply, coupler or outgoing feeder (MCCB) | up to 1600 A |
Outgoing feeder (drawer) | up to 630 A |
Motor starter, drawer | up to 315 kW |
Internal separation | Form 2b up to Form 4b Up to Form 4b type 7 |
Degree of protection | IP30 up to IP54 |